Municipal Courts

Administrative Violations - AV Codes


Legal Reference
New Code

Description

IBC 1003.3.1.5
BD1
FAILURE TO HAVE LANDING AT (DESCRIBE DOOR, I.E., INSIDE EXIT, ETC.)
DOOR
IBC 1003.3.1.8
BD2
FAILURE TO HAVE (KITCHEN, WEST, WEST WING OVER HANG, ETC.)
EXIT DOOR OPENABLE FROM THE INSIDE
IBC 1003.3.1.8
BD3
FAIL TO HAVE (I.E. KITCHEN, WEST, WEST WING OVER HANG..., ETC.)
EXIT DOOR OPENABLE FROM THE INSIDE
IBC 1003.3.1.9
BD4

LOCKING THE (I.E. WEST ENTRANCE, SOUTH WING OVER HANG OF.., ETC.)
EXIT DOOR OF A GROUP A OCCUPANCY

IBC 1003.3.1.9
BD5
LOCKING THE (I.E. WEST ENTRANCE, SOUTH WING OVER HANG OF, ETC.)
EXIT DOOR OF A GROUP A OCCUPANCY
IBC 1004.2
BD6
EXIT DOOR NOT IN OPERABLE CONDITION IN ACCORDANCE WITH BUILDING
CODE, TO-WIT:...
IBC 1004.3.2
BD7
FAIL TO HAVE CORRIDOR (WALLS/CEILINGS) CONSTRUCTED OF AT LEAST
ONE HOUR FIRE RESISTIVE CONSTRUCTION
IBC 1004.3.2.2
BD8
OBSTRUCT THE WIDTH OF A CORRIDOR
IBC 1005.2.1
BD9
FAIL TO HAVE AT LEAST # EXIT FOR THE (SECOND FLOOR/USABLE PORTION
OF BLD) AS REQ. BY THE BLD CODE
IBC 1005.2.1
BD10
FAIL TO HAVE AT LEAST # EXIT FOR THE (SECOND FLOOR/USABLE PORTION
OF A BLD) REQ. BY THE BLD CODE
IBC 101.4.3
BD11
FAIL TO HAVE HEATING APPARATUS CONFORM WITH INT. BLD. CODE TO-WIT:
STATE IN DETAIL THE SPEC.
IBC 105.1
BD12
(ERECT / ALTER /REPAIR /MOVE /IMPROVE / REMOVE / CONVERT /
DEMOLISH / CAUSE TO BE) A STRUCTURE W/OUT A PERMIT
IBC 105.7
BD13
FAIL TO KEEP ONE SET OF APPROVED BUILDING PLANS ON SITE
OF THE
BUILDING OR WORK
IBC 106.1.1.1
BD14
FAIL TO PROVIDE SET OF APPROVED PLANS FOR SPRINKLER SYSTEM
IBC 106.3
BD15
FAIL TO INSTALL SMOKE DETECTORS IN DWELLING /
CONGREGATE RES. (HOTEL / LODGING / GUEST ROOM) SLEEPING
USE
IBC 106.3.1
BD16
(CHANGE) (MODIFY) (ALTER) BUILDING PLANS WITHOUT
AUTHORIZATION FROM THE BUILDING OFFICIAL
IBC 110.1
BD17
NO CERTIFICATE OF OCCUPANCY
IBC 110.6
BD18
FAILURE TO POST CERTIFICATE OF OCCUPANCY
IBC 1106.1
BD19
FAILURE TO PROVIDE ACCESSIBLE PARKING SPACES
IBC 114.2
BD20
FAILURE TO COMPLY WITH A STOP ORDER ISSUED BY THE
BUILDING OFFICIAL
IBC 117.7.4
BD21
(OWNER / LESSEE) OPER. (ELEV / DUMBWAITER / ESCAL /
MAN LIFT / MANNA / PERSONNEL HOIST / CHAIR LIFT)
W/OUT PERMIT
IBC 2108.2
BD22
FAILURE TO PROVIDE APPROVED ATTIC ACCESS
IBC 3008.4.2
BD23
FAIL TO HAVE (ELEV) (DUMBWAITER) (ESCALATOR) OR
(MOVING WALK) INSPECTED ANNUALLY
IBC 302.1.1
BD24
OCC. CONTAIN (BOILER / CENTRAL HEAT PLANT / HOT-WATER
SUPPLY BOILER) NOT SEPARATED FROM REST OF BLD
IBC 302.1.1 {Table 302.1.1}
BD25
USE (LAB / SHOP) CONTAIN HAZ MAT W/OUT SEPARATING
FROM (ANOTHER LAB / PORTIONS) OF BLD BY ONE-HOUR FIRE
IBC 303.1
BD26
CLASSIFICATION GROUP A
IBC 303.1
BD27
USE (BUILD/PORTION OF BUILD) CLASSED IN GROUP A OCC.
WITH CONST. NOT IN TABLES 5-C AND 5-D, TO-WIT:
IBC 3110.14.3
BD28
FAILURE TO INSTALL WHEEL STOP NOT LESS THAN 2.5 FEET
FROM RIGHT-OF-WAY LINE
IBC 3110.14.4
BD29
ALLOWING STORM WATER DRAINAGE FROM A PARKING LOT TO
FLOW OVER (PUBLIC SIDEWALK / ADJOINING PROPERTY)
IBC 3110.3
BD30
(CONST. / CAUSE) (DRIVEWAY / SIDEWALK / PRIV. STR. /
PARKING LOT / ALLEY) CONNECT PRIV. PROP. WITH PUB. STR.
IBC 3202
BD31
PART OF STRUCTURE PROJECTING BEYOND THE PROPERTY
LINE OF THE BUILDING SITE
IBC 3202.2.4
BD32
(ERECT) (CONSTRUCT) (MAINTAIN) A STRUCTURE, TO-WIT:...
WHICH PROJECTED INTO AN ALLEY
IBC 3304.1
BD33
EXCAVATION/FILL FOR BLD OR STRUC. W/OUT CONST. /
PROTECTION SO IT WOULD NOT BE DANGER TO LIFE / PROP.
IBC 3304.1.4
BD34
(CONSTRUCT) (CAUSE TO BE CONSTRUCTED) A FILL FOR A
STRUCTURE WITHOUT PROTECTING ADJOINING PROPERTY
IBC 3307.1
BD35
DRAINING SURFACE WATER ONTO ADJACENT PROPERTY
W/OUT WRITTEN PERMISSION OF OWNER (NAME OF OWNER)
IBC 3311.4
BD36
FAILURE TO PROVIDE A TEMPORARY STANDPIPE FOR
BUILDING UNDER CONSTRUCTION
IBC 403.10
BD37
FAILURE TO HAVE AT LEAST 1 EMERGENCY GENERATOR
IBC 403.2
BD38
FAILURE TO PROVIDE MONITORING FOR SPRINKLER SYSTEM
WITH MORE THAN 100 SPRINKLER HEADS
IBC 707.5
BD39
FAILURE TO INSURE SHAFT ENCLOSURE WAS PROPERLY
EXTENDED AND ENCLOSED AT THE TOP AND BOTTOM
IBC 714.2.3
BD40
FAILURE TO HAVE 20 MINUTE FIRE-RATED DOORS IN
ONE-HOUR FIRE RESISTIVE CORRIDOR
IBC 716.4
BD41
FAILURE TO MAINTAIN DRAFT STOPS IN (ATTIC) (MANSARDS)
(OVERHANG) (OTHER CONCEALED ROOF SPACE)
IBC 901.5
BD42
FAILURE TO OBTAIN PERMIT FROM HFD FOR FIRE EXTINGUISHING SYSTEM
IBC 907.2.10.1.5
BD43
NOT HAVE COMBUSTION DETECTORS INTERCONNECTED
WITH FIRE ALARM IN (NURSERY / DAYCARE /
PRE-KINDERGARTEN)
IBC E103.1
BD44
PERFORM GRADING WITHOUT FIRST OBTAINING A PERMIT
IBC E106.4
BD45
PERFORM GRADING WITHOUT HAVING FIRST SUBMITTED
PLANS AND SUPPORTING DATA OF ENGINEERS REPORT
IBC E106.5
BD46
FAILURE TO SUBMIT SOIL ENGINEERING REPORT
IBC E106.6
BD47
FAILURE TO SUBMIT ENGINEERING GEOLOGY REPORT
IBC E106.7
BD48
FAIL TO PROVIDE SOIL OR LIQUEFACTION STUDY AS
REQUESTED BY THE BUILDING OFFICIAL
IBC E106.8
BD49
FAILURE TO SUBMIT A PLAN FOR A GRADING PERMIT
IBC E109.2
BD50
GRADING A SLOPE STEEPER THAN 1 UNIT VERTICAL IN 2 UNITS
HORIZONTAL WITHOUT SUBMITTING A REPORT
IBC E110.3
BD51
AMOUNTS OF ROCK OR SIMILAR IRREDUCIBLE MATERIAL
PERMITTED IN FILL
IBC E110.3
BD52
DETRIMENTAL AMOUNTS OF ORGANIC MATERIAL PERMITTED
IN FILL
IBC E110.4
BD53
FAIL TO COMPACT FILL TO A MINIMUM OF 90 PERCENT OF
MAXIMUM DENSITY
IBC E113.1
BD54
FAILURE TO PROPERLY MAINTAIN FACES OF CUT AND FILL
SLOPES FROM EROSION
IBC E113.2
BD55
FAILURE TO EMPLOY (CHECK DAM) (CRIBBING) (RIPRAP)
TO CONTROL EROSION AND PROVIDE SAFETY
IBC L101.2
BD56
(OWNER / CONTROL) FAIL COMPLY W/ WRIT. NOTICE
(OFFICIAL / FIRE MARSHALL / PEACE OFFICER) SECURE PROP.
IBC L101.2
BD57
BLD OWNER FAIL TO APPLY FOR LIFE SAFETY INSPEC. BY
(DEC. 31, 1991/ONE YEAR FROM ANNEXATION) (DATE)
IBC L101.2
BD58
FAIL AS (OWNER/AGENT OF OWNER) OF BUILDING TO BRING
THE BUILDING INTO FULL COMPLIANCE WITH 2 YEARS
IBC L101.3
BD59
(OWNER / AGENT) FAIL TO MAIN. BLD IN SAFE AND SANITARY
COND. (STATE SPECIFIC UNSAFE)
IBC L102.1
BD60
FAILURE TO HAVE AT LEAST TWO SEPARATE EXITS IN A
BUILDING WITH MORE THAN ONE FLOOR
IBC L103.1
BD61
FAIL TO HAVE OPENING THROUGH FLOOR IN A BLD ENCLOSED
IN A SHAFT ENCLOSURE OF FIRE-RESISTIVE CONST.
HBC 46.08
BD62
DISPLAY SPECTACULAR SIGN PROHIBITED
IBC 109.6
BD63
NO APPROVAL FOR WORK FROM BLDG OFFICIAL
ELC 206
EL1
BUSINESS LIC. VIO. - ELEC. CONTRACTOR NO SIGN ON VEH.
ELEC. CONTRACTOR NO SIGN ON COM. VEH.
ELC 206
EL2
ENGAGE IN (ELEC./SIGN) CONTRACTING HAVING NO PROPER
SIGN PERM. AFFIXED TO SERV. VEH. DIS. LIC. NUM.
ELC 301.1
EL3
(INSTALL / ALTER/REPAIR/REPLACE/REMODEL) ELECTRICAL
(SYSTEM / EQUIPMENT) W/OUT A CURRENT PERMIT
ELC 301.4
EL4
EMP. PERSON TO DO ELEC. MAIN. WORK W/OUT FIRST
OBTAINING ANNUAL PERMIT FOR LOC. ON WHICH EMP. WORKS
ELC 305(1)
EL5
FAIL TO CAUSE WORK TO BE ACCESSIBLE FOR INSPECTION
BY THE BUILDING OFFICIAL
ELC 305.1
EL6
CONCEAL PORTION OF ELEC. SYS. W/OUT FIRST HAVING
THE SYS. INSPECTED AND APPR. BY BLD OFFICIAL
ELC 401
EL7
PERFORMING ELECTRICAL WORK WITHOUT THE PROPER
LICENSE
ELC 401
EL8
PERFORM ELEC. (MAIN. / OUTSIDE / RES. / SIGN) WORK W/OUT
THE PROPER LIC.
ELC 402.5
EL9
SECURE PERMIT FOR ELEC. WORK NOT PERFORMED BY
MASTER (ELEC. / LINE ELEC. / SIGN ELEC. / LIC. EMP.)
ELC 403.1
EL10
FAILURE TO REGISTER AS AN ELECTRICAL CONTRACTOR
WITH THE CITY.
ELC 404.1
EL11
MASTER ELECTRICIAN MASTERING FOR MORE THAN ONE
ELECTRICAL CONTRACTOR AT ONE TIME
ELC 405.1
EL12
FAILURE TO REGISTER AS A MASTER ELECTRICIAN WITH
THE CITY OF HOUSTON.
ELC 406.1
EL13
NO SIGN MASTER ELECTRICIAN LICENSE
ELC 408.1
EL14
FAILURE TO REGISTER AS A JOURNEYMAN ELECTRICIAN
WITH THE CITY OF HOUSTON
ELC 409.1
EL15
NO JOURNEYMAN ELECTRICIAN LICENSE
ELC 411.1
EL16
NO APPRENTICE ELECTRICIAN LICENSE
ELC 412.1
EL17
CAUSE ANOTHER PERSON, TO-WIT: TO UNDER WORK AS A
MAINTENANCE ELECTRICIAN WITHOUT A PROPER LICENSE
EL 202
EL18
USE OF ELECTRICAL (SYSTEM/EQUIPMENT) WHICH CONSTITUTES
A HAZARD TO SAFETY HEALTH AND PUBLIC WELFARE
ELC 306.1
EL19
CONNECT TO A SOURCE OF ENERGY BEFORE HAVING
CONNECTION APPROVED BY BLDG OFFICIAL.
UMC 1005.0
ML1
FAILURE TO OBTAIN A PERMIT PRIOR TO (INSTALLATION)
(ALTERATION) (REPAIR) (REPLACMENT) OF A BOILER
UMC 1005.0
ML2
(INSTALL) (ALTER) (REPAIR) (REPLACE) A BOILER AND
PRESSURE VESSEL WITHOUT A PERMIT
UMC 1007.1
ML3
FAILURE TO PROVIDE AN AIR EXPANSION TANK FOR A
HOT-WATER HEATING SYSTEM
UMC 1008.0
ML4
FAILURE TO HAVE SAFETY VALVE ON A BOILER WHICH
CONFORMS TO ASME CODE AND STATE OF TEXAS BOILER LAW
UMC 1012.2
ML5
FAIL TO PROVIDE BOILER AND PRESSURE VESSEL WITH
REQUIRED NUMBER, SIZE AND CAPACITY OF SAFETY VALVE
UMC 1013.0
ML6
FAILURE TO EQUIP AUTOMATIC BOILER WITH CONTROLS
AND LIMIT DEVICES
UMC 1023.1
ML7
PLACING A BOILER INTO SERVICE WITHOUT GETTING IT
INSPECTED AND APPROVED BY THE BUILDING OFFICIAL
UMC 104.3
ML8
ALTER (USE / OCC.) OF A BLD W/OUT COMPLYING WITH THE
REQ.S OF THE CITY OF HOUSTON MECH. CODE, TO -WIT:
UMC 111.1
ML9
PERSON (CAUSE / PERMIT) PERSON TO (ERECT / CONST / ALTER / IMPROVE / DEMOLISH / USE OR MAIN.) A MECHANICAL SYS.
UMC 111.3
ML10
(INSTALL / ALTER / REPAIR) A MECH. (SYSTEM / APPLIANCE / COMPONENT / EQUIP.) W/OUT MAINTAIN MECH. INTEGRITY
UMC 112.0
ML11
(INSTALL / ALTER / REPAIR) MECH. SYS. (STATE TYPE OF SYS.,
I.E. AIR COND.) IN STRUC. W/OUT MECH. PERM.
UMC 116.2
ML12
FAIL TO REQUEST INSPEC. W/IN 48 HRS AFTER REPLACE / FIX
EXISTING MECH. EQUIP BEFORE PORTION CONCEALED
UMC 121.4
ML13
(INSTALL) (ALTER) (REPAIR) AN AIR-CONDITIONING SYSTEM
WITHOUT A CURRENT AIR CONDITIONING LICENSE
UMC 121.4
ML14
NO AIR CONDITIONING CONTRACTOR LICENSE
UMC 121.4
ML15
(PERSON/OWNER/AGENT/OCC.) AID AIR-COND. CONTRACTOR
IN VIO. MECH. CODE
UMC 121.5
ML16
FAIL TO NOTIFY/REGISTER AS LIC. AIR-COND. CONTRACTOR
WITH ADMIN. AUTH. BEFORE PERFORMING ANY WORK
UMC 121.7
ML17
LIC. AIR-COND CONTRACTOR (BE EMP BY/WORK FOR) MORE
THAN ONE BUS. ENTITY FOR PURPOSE TO OBTAIN PERMIT
UMC 121.7
ML18
(DIS. SIGN / USE ADVERTISING) INDICATED AUTH. TO ENGAGE
IN BUS. OF AIR-COND./REPAIR CONTRACTOR
UMC 121.8
ML19
FAIL TO IDENTIFY WITH PROPER SIGNS (AUTO. / TRUCK)
USED IN AIR COND./REPAIR CONTRACTOR
UMC 121.9
ML20
FAIL TO DELIVER COPY OF REC. OF WORK TO OWNER AS
LIC. AIR-COND. / REFRIGERATION CONTRACTOR
UMC 301
ML21
USE OF UNSAFE EQUIPMENT, TO-WIT:
UMC 301.0
ML22
HEATING NOT IN GOOD REPAIR
UMC 303.1
ML23
MAKE CONNECTIONS FROM SOURCE OF ENERGY FUEL TO
MECH. SYS. (AIR COND SYS / HEAT SYS / VENT SYS / FRIG SYS)
UMC 509.1
ML24
FAIL TO INSTALL HOOD ABOVE COM. TYPE (FRYER / BOILER /
GRILL / STEAM-JACKETED KETTLE / HOT-TOP RANGE / OVEN)
UMC 707.2
ML25
INSUFFICIENT SUPPLY OF COMBUSTION AIR FOR
FUEL-BURNING EQUIPMENT
UMC 801
ML26
FAILURE TO CONNECT AN APPLIANCE TO A VENTING SYSTEM
UMC 904.0
ML27
HEATING FAIL TO MEET BUILDING CODE
UPC 101.4.6 Prin #1
PB1
INSTALLING POTABLE WATER SUPPLY PIPING IN MANNER THAT
USED WATER COULD ENTER PIPING FROM RECEPTACLE
UPC 101.4.6 Prin #12
PB2
DISCHARGE WASTE FROM PLUMBING SYS. INTO (GROUND /
WATERWAY) W/OUT FIRST RENDERING THE WASTE INNOCUOUS
UPC 101.4.6 Prin #3
PB3
FAILURE TO PROVIDE MINIMUM SANITARY FACILITIES BASED
ON OCCUPANCY
UPC 101.5.1 & 101.5.5
PB4
FAILURE AS OWNER OCCUPANT TO INSTALL -XYZ- SO THAT IT
WILL FUNCTION PROPERLY
UPC 101.5.5
PB5
FAILURE TO MAINTAIN PLUMBING IN A GOOD STATE OF REPAIR,
TO-WIT:
UPC 101.5.5
PB6
FAIL OWNER / AGENT TO MAINTAIN PLUMBING AND DRAINAGE
SYSTEM IN A SANITARY AND SAFE OPER. CONDITION
UPC 1014.1
PB7
DRAIN COMMERCIAL KITCHEN GREASE INTO SANITARY WASTE
WITHOUT USING AN APPROVED INTERCEPTOR
UPC 1014.1
PB8
FAILURE TO HAVE GREASE TRAP INSTALLED IN A (RESTAURANT /
CAFE / CAFETERIA / BAR / CLUB / HOTEL / HOSPITAL)
UPC 1014.1
PB9
FAILURE TO INSTALL AN APPROVED LINT INTERCEPTOR
UPC 103.1
PB10
(INSTALL / ALTER / REPAIR / REPLACE / REMODEL / CAUSE TO BE) A PLUMBING SYSTEM W/OUT A PLUMBING PERMIT
UPC 103.3.2
PB11
NO PLAN FOR PLUMBING SYSTEM
UPC 103.3.2
PB12
FAIL TO KEEP ONE SET OF APPROVED PLUMBING PLANS ON
SITE OF THE BUILDING OR WORK
UPC 103.5.1.3
PB13
COVER WATER SUPPLY SYSTEM WITHOUT FIRST BEING TESTED
UPC 104.1
PB14
FAILURE TO REGISTER STATE PLUMBING LICENSE WITH THE
BUILDING OFFICIAL OF THE CITY OF HOUSTON
UPC 104.1
PB15
INSTALLING PLUMBING WITHOUT A PROPER LICENSE
UPC 104.6
PB16
FAILURE TO IDENTIFY PLUMBING BUSINESS VEHICLE WITH
PROPER SIGNS
UPC 1201.1
PB17
FAIL TO OBTAIN A PERMIT PRIOR TO PERFORMING A GAS TEST
ON A PLUMBING SYSTEM
UPC 316.1.3
PB18
USING PROHIBITED SOLDER IN WATER PIPING SYSTEM.
UPC 502.13
PB19
PLUMBING UTILITIES ORDINANCE/PRESSURE RELIEF VALUE
ON HOT WATERS PLUMBING
UPC 602.2
PB20
(MAKE CONN / ALLOW CONN TO EXIST) B/W (PIPE / CONDUIT)
CARRY DOME WATER SUPPLY BY (PUB / PRIV) WATER SERV
UPC 602.3
PB21
INSTALL WATER OPERATED MECHANISM -XYZ- WHICH MAY
CAUSE CONTAMINATION OF THE DOMESTIC WATER SUPPLY
UPC 603.0
PB22
USE WATER TREATING (CHEMICAL) (SUBSTANCE) WHICH MAY
CAUSE CONTAMINATION OF THE DOMESTIC WATER SUPPLY
UPC 603.1
PB23
INSTALL DEVICE FOR THE PREVENTION OF BACKFLOW
WITHOUT APPROVAL FROM THE ADMINISTRATIVE AUTHORITY
UPC 603.1
PB24
FAIL TO MAINTAIN A BACKFLOW (DEVICE) (ASSEMBLY) IN
GOOD WORKING CONDITION
UPC 603.1
PB25
REMOVE FROM USE A DEVICE INSTALLED IN A POTABLE
WATER SUPPLY SYSTEM W/OUT APPROVAL OF ADMIN. AUTH.
UPC 603.1
PB26
FAILURE AS RESPONSIBLE PERSON TO HAVE THE
BACKFLOW PREVENTION ASSEMBLY TESTED AT THE
TIME OF ALTER
UPC 603.3.7
PB27
FAILURE TO HAVE BACKFLOW PREVENTION ASSEMBLY IN
CONFORMITY TO LISTED STANDARDS : (STATE STANDARDS)
UPC 708
PB28
FAILURE TO PROPERLY GRADE THE YARD OF A DWELLING TO
INSURE THOROUGH DRAINAGE
UPC 1301.452(5)
PB29
EMPLOYING AN UNLICENSED, UNENDORSED OR
UNREGISTERED PERSON TO ENGAGE IN PLUMBING WORK